missing translation for 'onlineSavingsMsg'
Learn More

Periodsäure, 99 %, Thermo Scientific Chemicals

Artikelnummer. 11444387
Click to view available options
Menge:
50g
250g
1000g

Periodic acid is used as a component for glycoprotein stains. It serves as a pharmaceutical and synthetic intermediate and is used in silk screen printing. It acts as an oxidizing agent especially in the cleavage of 1,2 diols to prepare dialdehydes. It has selective oxidation powers which makes it an ideal reagent for the reclamation of silk screens in the printing industry. It finds application in life sciences for the analysis of intracellular polysaccharides like glycogen, starch and cellulose. Furthermore, it is used in oxidation reactions converting sulfides into sulfones, catalyzed by chromium(VI) oxide and oxidation reactions converting alcohols to aldehydes and ketones.

This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.

Anwendungen
Periodsäure wird als Komponente für die Glykoproteinfärbung verwendet. Sie dient als pharmazeutisches und synthetisches Zwischenprodukt und wird im Siebdruck verwendet. Sie fungiert als Oxidationsmittel, insbesondere bei der Spaltung von 1,2 Diolen zur Herstellung von Dialdehyden. Sie verfügt über selektive Oxidationskräfte und ist damit das ideale Reagenz für die Rückgewinnung von Siebdrucken in der Druckindustrie. Sie findet Anwendung in den Biowissenschaften bei der Analyse intrazellulärer Polysaccharide wie Glykogen, Stärke und Cellulose. Darüber hinaus wird sie bei Oxidationsreaktionen, die Sulfide in Sulfone umwandeln, katalysiert durch Chrom(VI)-oxid, und Oxidationsreaktionen verwendet, die Alkohole in Aldehyde und Ketone umwandeln.

Löslichkeit
Löslich in Wasser und Alkoholen.

Hinweise
Lichtempfindlich und hygroskopisch. Behälter an einem trockenen und gut belüfteten Ort dicht verschlossen halten. Nicht kompatibel mit starken Reduktionsmitteln, pulverförmigen Metallen, starken Basen und Dimethylsulfoxid.
TRUSTED_SUSTAINABILITY

Chemische Identifikatoren

CAS 10450-60-9
Summenformel H5IO6
Molekulargewicht (g/mol) 227.94
MDL-Nummer MFCD00011344
InChI-Schlüssel TWLXDPFBEPBAQB-UHFFFAOYSA-N
Synonym orthoperiodic acid, periodic acid, tetrahydroxyiodous acid, acid, periodic, paraperiodic acid, pentahydroxy-l5-iodane oxide, unii-ak1d44l87g, pentahydroxidooxidoiodine, hexaoxoiodic 5-acid, periodic acid, cryst
PubChem CID 25289
ChEBI CHEBI:29150
IUPAC-Name Pentahydroxy(oxo)-$l^{7}-Jod
SMILES O[I](O)(O)(O)(O)=O

Spezifikation

Chemischer Name oder Material Periodic acid
pH 1,2
Schmelzpunkt 126°bis 130 °C
Geruch Geruchsneutral
Empfindlichkeit Hygroskopisch; lichtempfindlich
Menge 50g
UN-Nummer UN3085
Merck Index 14,7171
Löslichkeitsinformationen Soluble in water and alcohols.
Formelmasse 227.94
Reinheit (%) 99%
Mehr anzeigen Weniger anzeigen
compliance-icons compliance-icons compliance-icons
Produktidentifikator
  • Periodic acid
Signalwort
  • Gefahr
Gefahrenkategorie
  • LANGFRISTIG GEWÄSSERGEFÄHRDEND Chronisch 1
  • AKUT GEWÄSSERGEFÄHRDEND Akut 1
  • Schwere Augenschädigung/Augenreizung Kategorie 1
  • Oxidierender Feststoff Kategorie 1
  • Hautreizende/-ätzende Wirkung Kategorie 1C
Gefahrenhinweis
  • H271-Kann Brand oder Explosion verursachen; starkes Oxidationsmittel.
  • H314-Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
  • H318-Verursacht schwere Augenschäden.
  • H400-Sehr giftig für Wasserorganismen.
  • H410-Sehr giftig für Wasserorganismen mit langfristiger Wirkung.
Sicherheitshinweis
  • P210-Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen ndquellen fernhalten. Nicht rauchen.
  • P280-Schutzhandschuhe/Schutzkleidung/Augenschutz/Gesichtsschutz tragen.
  • P301+P330+P331-BEI VERSCHLUCKEN: Mund ausspülen. KEIN Erbrechen herbeiführen.
  • P303+P361+P353-BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen/duschen.
  • P305+P351+P338-BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen.
  • P310-Sofort GIFTINFORMATIONSZENTRUM/Arzt/anrufen.
Ergänzende Informationen
  • MIXTURE LIST-Enthält: periodic acid

RUO – Research Use Only

Berichtigung von Produktinhalten

Bitte geben Sie uns Ihr Feedback zu den Produktinhalten, indem Sie das folgende Formular ausfüllen.

Name des Produkts

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.

Vielen Dank, dass Sie uns helfen, unsere Website zu verbessern. Ihr Feedback wurde übermittelt